全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...
Clinics  2012 

Clinical predictors of prosthesis-patient mismatch after aortic valve replacement for aortic stenosis

DOI: 10.6061/clinics/2012(01)09

Keywords: aortic stenosis, patient prosthesis mismatch, bioprosthesis female, gender clinical predictors.

Full-Text   Cite this paper   Add to My Lib

Abstract:

objective: we sought to ascertain predictors of patient prosthesis mismatch, an independent predictor of mortality, in patients with aortic stenosis using bioprosthetic valves. method: we analyzed 2,107 sequential surgeries. patient prosthesis mismatch was calculated using the effective orifice area of the prosthesis divided by the patient's body surface area. we defined nonsignificant, moderate, and severe patient prosthesis mismatch as effective orifice area indexes of .0.85 cm2/m, 0.85-0.66 cm2/m2, and <0.65 cm2/m2, respectively. results: a total of 311 bioprosthetic patients were identified. the incidence of nonsignificant, moderate, and severe patient prosthesis mismatch was 41%, 42, and 16%, respectively. severe patient prosthesis mismatch was significantly more prevalent in females (82%). in severe patient prosthesis mismatch, the perfusion and the crossclamp times were considerably lower when compared with nonsignificant patient prosthesis mismatch and moderate patient prosthesis mismatch. patients with severe patient prosthesis mismatch had a significantly higher likelihood of spending time in the intensive care unit and a significantly longer length of stay in the hospital. body surface area was not different in severe patient prosthesis mismatch when compared with nonsignificant patient prosthesis mismatch. in-hospital mortality in patients with nonsignificant, moderate, and severe patient prosthesis mismatch was 2.3%, 6.1%, and 8%, respectively. minimally invasive surgery was significantly associated with moderate patient prosthesis mismatch in 49% of the patients, but not with severe patient prosthesis mismatch. conclusion: severe patient prosthesis mismatch is more common in females, but not in those with minimal available body surface area. though operative times were shorter in these patients, intensive care unit and hospital lengths of stay were longer. surgeons and cardiologists should be cognizant of these clinical predictors and complications pri

Full-Text

comments powered by Disqus

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133

WeChat 1538708413