全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...

Analytical Assessment of DC Components Generated by Renewable Energy Resources with Inverter-Based Interconnection System due to Even Harmonics

DOI: 10.5402/2012/261325

Full-Text   Cite this paper   Add to My Lib

Abstract:

This paper deals with the assessment of DC components generated by renewable energy resources with inverter-based interconnection system to the electric grid. DC injection is a critical issue related to power quality of distribution network systems with high penetration of inverter-based interconnection systems. This type of interface systems may improve the performance of the electric generation unit and affect positively or negatively the power quality of the distribution network depending on the proper or improper designation. The investigation of the various causes of DC components and the analytical assessment of their maximum levels are crucial for the proper operation of inverter-based interface systems and the limitation of DC injection. A method based on analytical calculations using a computer software has been implemented for the assessment of DC components contained on an inverter's output voltage when even harmonics are present on the network voltage. Moreover, a simulation package was used to demonstrate the existence of DC components under various conditions. It was proved by the current analysis that the amounts of DC components generated when even harmonics are present on the network voltage can be high under abnormalities on the power grid but they are not considerable under normal operating conditions. 1. Introduction The need for analysis and assessment of DC components on voltage and/or current, which may appear at electric grids, aroused mainly due to the significant problems they result in. Power transformers are the power system element which is mainly affected by the presence of DC components. Saturation, generation of harmonics, power losses, reduction in life cycle, and increasing noise levels are some of the effects on transformers introduced by the presence of DC components. Moreover, the saturation of current transformers used by measurement devices of control and protection of electric grid equipment may cause inaccurate measurements with considerable consequences. In cases where many DC injection sources are connected to the grid, the need for limitation and standardization becomes urgent. Such cases include the interconnection of several distributed generation units at Medium-Voltage (MV) or Low-Voltage (LV) level through inverters based on the technology of power electronics. Those inverters may generate DC components on the output voltage during abnormal conditions that will lead to DC current injection flowing to the electric grid if no power transformer is used between the inverter and the grid (transformer-less

References

[1]  E. Spooner, “A New Australian Standard for Small Grid-connected Renewable Generation Systems Connected via Inverters,” 2001, http://www.acre.ee.unsw.edu.au/acrelab/Assets/Papers/142_Spooner_AUPEC01_Final2.pdf.
[2]  T. Nakajima, K. I. Suzuki, M. Yajima, N. Kawakami, K. I. Tanomura, and S. Irokawa, “A new control method preventing transformer DC magnetization for voltage source self-commutated converters,” IEEE Transactions on Power Delivery, vol. 11, no. 3, pp. 1522–1528, 1996.
[3]  K. H. Sobrink, N. Jenkins, F. C. A. Schettler, J. Pedersen, K. O. H. Pedersen, and K. Bergmann, “Reactive power compensation of a 24 MW wind farm using a 12-pulse voltage source converter,” in Proceedings of the International Conference Large High Voltage Electric Systems (CIGRé '98), 1998.
[4]  M. Rashid, Power Electronics Handbook, 3rd edition, 2011.
[5]  J. A. Orr and A. E. Emanuel, “On the need for strict second harmonic limits,” IEEE Transactions on Power Delivery, vol. 15, no. 3, pp. 967–971, 2000.
[6]  S. Lu, Y. Liu, and J. D. L. Ree, “Harmonics generated from a DC biased transformer,” IEEE Transactions on Power Delivery, vol. 8, no. 2, pp. 725–731, 1993.
[7]  E. V. Larsen, R. A. Walling, and C. J. Bridenbaugh, “Parallel AC/DC transmission lines steady-state induction issues,” IEEE Transactions on Power Delivery, vol. 4, no. 1, pp. 667–674, 1989.
[8]  PSCAD/EMTDC User's Guide, “Manitoba HVDC Research Centre,” Version 4. 7, 2010.
[9]  MathCad User's Guide, “Parametric Technology Corporation (PTC),” Version 14, 2007.
[10]  N. Mohan, T. Undeland, and W. Robbins, Power Electronics: Converters, Applications, and Design, John Wiley & Sons, New York, NY, USA, 1995.
[11]  P. R. Price, “Geomagnetically induced current effects on transformers,” IEEE Transactions on Power Delivery, vol. 17, no. 4, pp. 1002–1008, 2002.
[12]  E. Styvaktakis, Automating Power Quality Analysis [Ph.D. thesis], Chalmers University of Technology, Gothenburg, Sweden, 2002.
[13]  W. Xu, T. G. Martinich, J. H. Sawada, and Y. Mansour, “Harmonics from SVC transformer saturation with direct current offset,” IEEE Transactions on Power Delivery, vol. 9, no. 3, pp. 1502–1509, 1994.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133