全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...
Materials  2014 

Cytotoxicity Test of One-Step Self-Etching Bonding Agents by Standardized Dentin Barrier Test Using Polyurethane Discs

DOI: 10.3390/ma7010085

Keywords: cytotoxicity test, dentin barrier test, dentin substitute, one-step self-etching bonding agent, perfusion cell culture

Full-Text   Cite this paper   Add to My Lib

Abstract:

This study was performed to standardize a dentin barrier test with the substitute and evaluate the cytotoxicity of one-step self-etching bonding agents. Each of the natural bovine dentin and polyurethane discs were 500-μm thick and were tested using a perfusion device. Following the treatment with 0.05% phenol on the natural bovine disc or three kinds of polyurethane discs—30, 40, and 50 pcf (pounds per cubic foot)—cell viability of L-929 was measured by the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay and expressed as percentages of non-treated group, respectively. A substitute showing permeability similar to that of bovine dentin was determined based on this result. Cytotoxicity test of bonding agents was performed by the selected substitute, the results of which were expressed as percentages of the control. In addition, SEM images were taken after the tests. The cell viability by 40-pcf polyurethane disc was not statistically different from that by bovine dentin disc ( P > 0.05). Futurabond DC resulted in the highest cell viability and Bond force the lowest by the 40-pcf polyurethane disc ( P < 0.05). The adhesives on the 40-pcf polyurethane disc changed cellular morphology with different degrees on the SEM images. This standardized test might be useful for assessing the cytotoxicity of dental materials applied to dentin before clinical applications.

References

[1]  Dentistry-Vocabulary; ISO; International Organization for Standardization: Geneva, Switzerland.
[2]  Vajrabhaya, L.; Sithisarn, P. Multilayer and monolayer cell cultures in a cytotoxicity assay of root canal sealers. Int. Endod. J?1997, 30, 141–144, doi:10.1046/j.1365-2591.1997.00056.x. 10332248
[3]  Eldeniz, A.U.; Mustafa, K.; Orstavik, D.; Dahl, J.E. Cytotoxicity of new resin-, calcium hydroxide- and silicone-based root canal sealers on fibroblasts derived from human gingiva and L929 cell lines. Int. Endod. J?2007, 40, 329–337, doi:10.1111/j.1365-2591.2007.01211.x. 17309743
[4]  Williams, D.F. On the mechanisms of biocompatibility. Biomaterials?2008, 29, 2941–2953, doi:10.1016/j.biomaterials.2008.04.023. 18440630
[5]  Schmalz, G.; Schuster, U.; Thonemann, B.; Barth, M.; Esterbauer, S. Dentin barrier test with transfected bovine pulp-derived cells. J. Endod?2001, 27, 96–102, doi:10.1097/00004770-200102000-00009. 11491647
[6]  Schuster, U.; Schmalz, G.; Thonemann, B.; Mendel, N.; Metzl, C. Cytotoxicity testing with three-dimensional cultures of transfected pulp-derived cells. J. Endod?2001, 27, 259–265, doi:10.1097/00004770-200104000-00004. 11485263
[7]  Tay, F.R.; King, N.M.; Suh, B.I.; Pashley, D.H. Effect of delayed activation of light-cured resin composites on bonding of all-in-one adhesives. J. Adhes. Dent?2001, 3, 207–225. 11803709
[8]  Pfuhler, S.; Fautz, R.; Ouedraogo, G.; Latil, A.; Kenny, J.; Moore, C.; Diembeck, W.; Hewitt, N.J.; Reisinger, K.; Barroso, J. The cosmetics Europe strategy for animal-free genotoxicity testing: Project status up-date. Toxicol. In Vitro?2013, 28, doi:10.1016/j.tiv.2013.06.004.
[9]  Casas, J.W.; Lewerenz, G.M.; Rankin, E.A.; Willoughby, J.A., Sr.; Blakeman, L.C.; McKim, J.M., Jr.; Coleman, K.P. In vitro human skin irritation test for evaluation of medical device extracts. Toxicol. ?2013, 27, doi:10.1016/j.tiv.2013.08.006.
[10]  Schmalz, G.; Schuster, U.; Koch, A.; Schweikl, H. Cytotoxicity of low pH dentin-bonding agents in a dentin barrier test in vitro. J. Endod?2002, 28, 188–192, doi:10.1097/00004770-200203000-00011. 12017178
[11]  Ulker, H.E.; Sengun, A. Cytotoxicity evaluation of self adhesive composite resin cements by dentin barrier test on 3D pulp cells. Eur. J. Dent?2009, 3, 120–126. 19421392
[12]  Sengun, A.; Yalcin, M.; Ulker, H.E.; Ozturk, B.; Hakki, S.S. Cytotoxicity evaluation of dentin bonding agents by dentin barrier test on 3-dimensional pulp cells. Oral Surg. Oral Med. Oral Pathol. Oral Radiol. Endod?2011, 112, e83–e88, doi:10.1016/j.tripleo.2011.02.023. 21546285
[13]  Nakamichi, I.; Iwaku, M.; Fusayama, T. Bovine teeth as possible substitutes in the adhesion test. J. Dent. Res?1983, 62, 1076–1081, doi:10.1177/00220345830620101501. 6352757
[14]  Haapasalo, M.; Orstavik, D. In vitro infection and disinfection of dentinal tubules. J. Dent. Res?1987, 66, 1375–1379, doi:10.1177/00220345870660081801. 3114347
[15]  Kim, M.J.; Kim, K.N.; Lee, Y.K.; Kim, K.M. Cytotoxicity test of dentin bonding agents using millipore filters as dentin substitutes in a dentin barrier test. Clin. Oral Investig?2013, 17, 1489–1496, doi:10.1007/s00784-012-0840-z. 23011524
[16]  Millich, F.; Jeang, L.; Eick, J.D.; Chappelow, C.C.; Pinzino, C.S. Elements of light-cured epoxy-based dental polymer systems. J. Dent. Res?1998, 77, 603–608, doi:10.1177/00220345980770041301. 9539463
[17]  Yeh, H.W.; Chang, M.C.; Lin, C.P.; Tseng, W.Y.; Chang, H.H.; Wang, T.M.; Chen, Y.J.; Lin, C.C.; Yang, T.T.; Lin, L.D.; et al. Comparative cytotoxicity of five current dentin bonding agents: role of cell cycle deregulation. Acta Biomater?2009, 5, 3404–3410, doi:10.1016/j.actbio.2009.05.036. 19497393
[18]  Galler, K.; Hiller, K.A.; Ettl, T.; Schmalz, G. Selective influence of dentin thickness upon cytotoxicity of dentin contacting materials. J. Endod?2005, 31, 396–399, doi:10.1097/01.don.0000145428.26880.e5. 15851937
[19]  Moodley, D.; Grobler, S.R.; Olivler, A. Cytotoxicity of a dentine bonding agent on four different cell-lines. SADJ?2005, 60, 234–236. 16119020
[20]  Porto, I.C.; Oliveira, D.C.; Raele, R.A.; Ribas, K.H.; Montes, M.A.; de Castro, C.M. Cytotoxicity of current adhesive systems: In vitro testing on cell cultures of primary murine macrophages. Dental Mater?2011, 27, 221–228, doi:10.1016/j.dental.2010.10.006.
[21]  Chen, R.S.; Liu, C.C.; Tseng, W.Y.; Jeng, J.H.; Lin, C.P. Cytotoxicity of three dentin bonding agents on human dental pulp cells. J. Dent?2003, 31, 223–229, doi:10.1016/S0300-5712(02)00088-X. 12726708
[22]  Kim, N.R.; Park, H.C.; Kim, I.; Lim, B.S.; Yang, H.C. In vitro cytocompatibility of N-acetylcysteine-supplemented dentin bonding agents. J. Endod?2010, 36, 1844–1850, doi:10.1016/j.joen.2010.08.005. 20951298
[23]  Demirci, M.; Hiller, K.A.; Bosl, C.; Galler, K.; Schmalz, G.; Schweikl, H. The induction of oxidative stress, cytotoxicity, and genotoxicity by dental adhesives. Dental Mater?2008, 24, 362–371, doi:10.1016/j.dental.2007.06.009.
[24]  Sigusch, B.W.; Pflaum, T.; Volpel, A.; Schinkel, M.; Jandt, K.D. The influence of various light curing units on the cytotoxicity of dental adhesives. Dental Mater?2009, 25, 1446–1452, doi:10.1016/j.dental.2009.06.016.
[25]  Schmalz, G.; Schuster, U.; Nuetzel, K.; Schweikl, H. An in vitro pulp chamber with three-dimensional cell cultures. J. Endod?1999, 25, 24–29, doi:10.1016/S0099-2399(99)80394-X. 10196839
[26]  Biological Evaluation of Medical Devices—Part 12: Sample Preparation and Reference Materials; ISO 10993-12; International Organization for Standardization: Geneva, Switzerland, 2012.
[27]  Mjor, I.A. Biologic assessment of restorative dental materials: Interrelationship of biologic and technologic properties. Oper. Dent?1978, 3, 9–13. 112585
[28]  Lenzi, T.L.; Guglielmi, C.D.; Arana-Chavez, V.E.; Raggio, D.P. Tubule density and diameter in coronal dentin from primary and permanent human teeth. Microsc. Microanal?2013, 19, doi:10.1017/S1431927613012725.
[29]  Schmalz, G.; Garhammer, P.; Schweiki, H. A commercially available cell culture device modified for dentin barrier tests. J. Endod?1996, 22, 249–252, doi:10.1016/S0099-2399(06)80142-1. 8632137

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133