Respiratory-gated radiotherapy offers a significant potential for improvement in the irradiation of tumor sites affected by respiratory motion such as lung, breast, and liver tumors. An increased conformality of irradiation fields leading to decreased complication rates of organs at risk is expected. Five main strategies are used to reduce respiratory motion effects: integration of respiratory movements into treatment planning, forced shallow breathing with abdominal compression, breath-hold techniques, respiratory gating techniques, and tracking techniques. Measurements of respiratory movements can be performed either in a representative sample of the general population, or directly on the patient before irradiation. Reduction of breathing motion can be achieved by using either abdominal compression, breath-hold techniques, or respiratory gating techniques. Abdominal compression can be used to reduce diaphragmatic excursions. Breath-hold can be achieved with active techniques, in which airflow of the patient is temporarily blocked by a valve, or passive techniques, in which the patient voluntarily breath-holds. Respiratory gating techniques use external devices to predict the phase of the breathing cycle while the patient breathes freely. Another approach is tumor-tracking technique, which consists of a real-time localization of a constantly moving tumor. This work describes these different strategies and gives an overview of the literature. 1. Introduction Taking into account the respiratory movements has always been a major concern of thoracic radiotherapy. The development of conformal radiotherapy using reduced radiation fields, with or without intensity modulation, and above all the growing interest for hypofractionated stereotactic body radiotherapy, further enhanced this concern [1–4]. In 1987, an American team noticed that treatment in deep inspiration spared parts of the lungs, and they suggested a need to develop “Radiotherapy Gated to Respiration” [5]. The term “gating” was subsequently used to designate a variety of different practices. The first technique designed to control respiratory movements was developed in Japan in 1989. It consisted of an airbag system designed to synchronize radiotherapy, but it was not further developed [6]. Five main strategies are currently used to reduce respiratory motion effects: integration of respiratory movements into treatment planning (geometrical or dosimetric), forced shallow breathing with abdominal compression, breath-hold techniques (active or voluntary), respiratory gating techniques, and tracking
References
[1]
P. Giraud, E. Yorke, S. Jiang, L. Simon, K. Rosenzweig, and G. Mageras, “Reduction of organ motion effects in IMRT and conformal 3D radiation delivery by using gating and tracking techniques,” Cancer/Radiotherapie, vol. 10, no. 5, pp. 269–282, 2006.
[2]
K. M. Langen and D. T. Jones, “Organ motion and its management,” International Journal of Radiation Oncology, Biology and Physics, vol. 50, no. 1, pp. 265–278, 2001.
[3]
M. Goitein, “Organ and tumor motion: an overview,” Seminars in Radiation Oncology, vol. 14, no. 1, pp. 2–9, 2004.
[4]
F. Reboul, L. Mineur, J. B. Paoli, V. Bodez, R. Oozeer, and R. Garcia, “Thoracic radiotherapy and breath control: current prospects,” Cancer/Radiotherapie, vol. 6, no. 1, pp. 135s–139s, 2002.
[5]
C. G. Willett, R. M. Linggood, M. A. Stracher et al., “The effect of the respiratory cycle on mediastinal and lung dimensions in Hodgkin's disease. Implications for radiotherapy gated to respiration,” Cancer, vol. 60, no. 6, pp. 1232–1237, 1987.
[6]
K. Ohara, T. Okumura, M. Akisada et al., “Irradiation synchronized with respiration gate,” International Journal of Radiation Oncology, Biology and Physics, vol. 17, no. 4, pp. 853–857, 1989.
[7]
ICRU REPORT 83, “Prescribing, recording, and reporting. Photon-beam intensity-modulated radiation therapy (IMRT),” Journal of the ICRU, vol. 10, no. 1, 2010.
[8]
J. Chavaudra and A. Bridier, “Definition of volumes in external radiotherapy: ICRU reports 50 and 62,” Cancer/Radiotherapie, vol. 5, no. 5, pp. 472–478, 2001.
[9]
I. Suramo, M. Paivansalo, and V. Myllyla, “Cranio-caudal movements of the liver, pancreas and kidneys in respiration,” Acta Radiologica—Series Diagnosis, vol. 25, no. 2, pp. 129–131, 1984.
[10]
S. C. Davies, A. L. Hill, R. B. Holmes, M. Halliwell, and P. C. Jackson, “Ultrasound quantitation of respiratory organ motion in the upper abdomen,” The British Journal of Radiology, vol. 67, no. 803, pp. 1096–1102, 1994.
[11]
J. M. Balter, K. L. Lam, C. J. McGinn, T. S. Lawrence, and R. K. Ten Haken, “Improvement of CT-based treatment-planning models of abdominal targets using static exhale imaging,” International Journal of Radiation Oncology, Biology and Physics, vol. 41, no. 4, pp. 939–943, 1998.
[12]
R. Wagman, E. Yorke, E. Ford et al., “Respiratory gating for liver tumors: use in dose escalation,” International Journal of Radiation Oncology, Biology and Physics, vol. 55, no. 3, pp. 659–668, 2003.
[13]
S. Shimizu, H. Shirato, K. Kagei et al., “Impact of respiratory movement on the computed tomographic images of small lung tumors in three-dimensional (3D) radiotherapy,” International Journal of Radiation Oncology, Biology and Physics, vol. 46, no. 5, pp. 1127–1133, 2000.
[14]
P. Giraud, Y. de Rycke, B. Dubray et al., “Conformal radiotherapy (CRT) planning for lung cancer: analysis of intrathoracic organ motion during extreme phases of breathing,” International Journal of Radiation Oncology, Biology and Physics, vol. 51, no. 4, pp. 1081–1092, 2001.
[15]
E. C. Ford, G. S. Mageras, E. Yorke, K. E. Rosenzweig, R. Wagman, and C. C. Ling, “Evaluation of respiratory movement during gated radiotherapy using film and electronic portal imaging,” International Journal of Radiation Oncology, Biology and Physics, vol. 52, no. 2, pp. 522–531, 2002.
[16]
E. A. Barnes, B. R. Murray, D. M. Robinson, L. J. Underwood, J. Hanson, and W. H. Y. Roa, “Dosimetric evaluation of lung tumor immobilization using breath hold at deep inspiration,” International Journal of Radiation Oncology, Biology and Physics, vol. 50, no. 4, pp. 1091–1098, 2001.
[17]
L. Ekberg, O. Holmberg, L. Wittgren, G. Bjelkengren, and T. Landberg, “What margins should be added to the clinical target volume in radiotherapy treatment planning for lung cancer?” Radiotherapy and Oncology, vol. 48, no. 1, pp. 71–77, 1998.
[18]
S. Malone, J. M. Crook, W. S. Kendal, and J. Szanto, “Respiratory-induced prostate motion: quantification and characterization,” International Journal of Radiation Oncology, Biology and Physics, vol. 48, no. 1, pp. 105–109, 2000.
[19]
P. J. Bryan, S. Custar, J. R. Haaga, and V. Balsara, “Respiratory movement of the pancreas: an ultrasonic study,” Journal of Ultrasound in Medicine, vol. 3, no. 7, pp. 317–320, 1984.
[20]
C. C. Ling, E. Yorke, H. Amols et al., “High-tech will improve radiotherapy of NSCLC: a hypothesis waiting to be validated,” International Journal of Radiation Oncology, Biology and Physics, vol. 60, no. 1, pp. 3–7, 2004.
[21]
V. M. Remouchamps, F. A. Vicini, M. B. Sharpe, L. L. Kestin, A. A. Martinez, and J. W. Wong, “Significant reductions in heart and lung doses using deep inspiration breath hold with active breathing control and intensity-modulated radiation therapy for patients treated with locoregional breast irradiation,” International Journal of Radiation Oncology, Biology and Physics, vol. 55, no. 2, pp. 392–406, 2003.
[22]
T. Bortfeld, S. B. Jiang, and E. Rietzel, “Effects of motion on the total dose distribution,” Seminars in Radiation Oncology, vol. 14, no. 1, pp. 41–51, 2004.
[23]
J. Mechalakos, E. Yorke, G. S. Mageras et al., “Dosimetric effect of respiratory motion in external beam radiotherapy of the lung,” Radiotherapy and Oncology, vol. 71, no. 2, pp. 191–200, 2004.
[24]
H. Shirato, Y. Seppenwoolde, K. Kitamura, R. Onimura, and S. Shimizu, “Intrafractional tumor motion: lung and liver,” Seminars in Radiation Oncology, vol. 14, no. 1, pp. 10–18, 2004.
[25]
P. Giraud, S. Helfre, V. Servois et al., “Evaluation of intrathoracic organs mobility using CT gated by a spirometer,” in Proceedings of the 19th ESTRO, Istanbul, Turkey, 2000.
[26]
E. D. Yorke, L. Wang, K. E. Rosenzweig, D. Mah, J. B. Paoli, and C. S. Chui, “Evaluation of deep inspiration breath-hold lung treatment plans with Monte Carlo dose calculation,” International Journal of Radiation Oncology, Biology and Physics, vol. 53, no. 4, pp. 1058–1070, 2002.
[27]
J. Hanley, M. M. Debois, D. Mah et al., “Deep inspiration breath-hold technique for lung tumors: the potential value of target immobilization and reduced lung density in dose escalation,” International Journal of Radiation Oncology, Biology and Physics, vol. 45, no. 3, pp. 603–611, 1999.
[28]
J. Leong, “Implementation of random positioning error in computerised radiation treatment planning systems as a result of fractionation,” Physics in Medicine and Biology, vol. 32, no. 3, pp. 327–324, 1987.
[29]
H. Blomgren, I. Lax, I. Naslund, and R. Svanstrom, “Stereotactic high dose fraction radiation therapy of extracranial tumors using an accelerator. Clinical experience of the first thirty-one patients,” Acta Oncologica, vol. 34, no. 6, pp. 861–870, 1995.
[30]
J. P. Bissonnette, K. N. Franks, T. G. Purdie et al., “Quantifying interfraction and intrafraction tumor motion in lung stereotactic body radiotherapy using respiration-correlated cone beam computed tomography,” International Journal of Radiation Oncology, Biology and Physics, vol. 75, no. 3, pp. 688–695, 2009.
[31]
I. Lax, “Target dose versus extratarget dose in stereotactic radiosurgery,” Acta Oncologica, vol. 32, no. 4, pp. 453–457, 1993.
[32]
Y. Negoro, Y. Nagata, T. Aoki et al., “The effectiveness of an immobilization device in conformal radiotherapy for lung tumor: reduction of respiratory tumor movement and evaluation of the daily setup accuracy,” International Journal of Radiation Oncology, Biology and Physics, vol. 50, no. 4, pp. 889–898, 2001.
[33]
P. Keall, “4-dimensional computed tomography imaging and treatment planning,” Seminars in Radiation Oncology, vol. 14, no. 1, pp. 81–90, 2004.
[34]
P. Giraud, L. Simon, M. Saliou et al., “Respiratory gated radiotherapy: the 4D radiotherapy,” Bulletin du Cancer, vol. 92, no. 1, pp. 83–89, 2005.
[35]
T. Tada, K. Minakuchi, T. Fujioka et al., “Lung cancer: intermittent irradiation synchronized with respiratory motion—results of a pilot study,” Radiology, vol. 207, no. 3, pp. 779–783, 1998.
[36]
G. S. Sharp, S. B. Jiang, S. Shimizu, and H. Shirato, “Prediction of respiratory tumour motion for real-time image-guided radiotherapy,” Physics in Medicine and Biology, vol. 49, no. 3, pp. 425–440, 2004.
[37]
G. C. Sharp, S. B. Jiang, S. Shimizu, and H. Shirato, “Tracking errors in a prototype real-time tumour tracking system,” Physics in Medicine and Biology, vol. 49, no. 23, pp. 5347–5356, 2004.
[38]
J. W. Wong, M. B. Sharpe, D. A. Jaffray et al., “The use of active breathing control (ABC) to reduce margin for breathing motion,” International Journal of Radiation Oncology, Biology and Physics, vol. 44, no. 4, pp. 911–919, 1999.
[39]
R. Garcia, R. Oozeer, H. L. Thanh et al., “Radiotherapy of lung cancer: the inspiration breath hold with a spirometric monitoring,” Cancer/Radiotherapie, vol. 6, no. 1, pp. 30–38, 2002.
[40]
K. E. Rosenzweig, J. Hanley, D. Mah et al., “The deep inspiration breath-hold technique in the treatment of inoperable non-small-cell lung cancer,” International Journal of Radiation Oncology, Biology and Physics, vol. 48, no. 1, pp. 81–87, 2000.
[41]
D. Mah, J. Hanley, K. E. Rosenzweig et al., “Technical aspects of the deep inspiration breath-hold technique in the treatment of thoracic cancer,” International Journal of Radiation Oncology, Biology and Physics, vol. 48, no. 4, pp. 1175–1185, 2000.
[42]
V. R. Kini, S. S. Vedam, P. J. Keall, S. Patil, C. Chen, and R. Mohan, “Patient training in respiratory-gated radiotherapy,” Medical Dosimetry, vol. 28, no. 1, pp. 7–11, 2003.
[43]
M. J. Murphy, “Tracking moving organs in real time,” Seminars in Radiation Oncology, vol. 14, no. 1, pp. 91–100, 2004.
[44]
P. H. Quanjer, G. J. Tammeling, J. E. Cotes, O. F. Pedersen, R. Peslin, and J. C. Yernault, “Lung volumes and forced ventilatory flows. Report working party standardization of lung function tests, european community for steel and coal. Official statement of the european respiratory society,” The European Respiratory Journal Supplements, vol. 16, pp. 5–40, 1993.
[45]
G. S. Mageras, E. Yorke, K. Rosenzweig et al., “Fluoroscopic evaluation of diaphragmatic motion reduction with a respiratory gated radiotherapy system,” Journal of Applied Clinical Medical Physics, vol. 2, no. 4, pp. 191–200, 2001.
[46]
L. Papiez, “The leaf sweep algorithm for an immobile and moving target as an optimal control problem in radiotherapy delivery,” Mathematical and Computer Modelling, vol. 37, no. 7-8, pp. 735–745, 2003.
[47]
B. Warkentin, P. Stavrev, N. Stavreva, C. Field, and B. G. Fallone, “A TCP-NTCP estimation module using DVHs and known radiobiological models and parameter sets,” Journal of Applied Clinical Medical Physics, vol. 5, no. 1, pp. 50–63, 2004.
[48]
S. D. McCarter and W. A. Beckham, “Evaluation of the validity of a convolution method for incorporating tumour movement and set-up variations into the radiotherapy treatment planning system,” Physics in Medicine and Biology, vol. 45, no. 4, pp. 923–931, 2000.
[49]
I. J. Chetty, M. Rosu, D. L. McShan, B. A. Fraass, J. M. Balter, and R. K. Ten Haken, “Accounting for center-of-mass target motion using convolution methods in Monte Carlo-based dose calculations of the lung,” Medical Physics, vol. 31, no. 4, pp. 925–932, 2004.
[50]
B. S. Yi, J. Perks, R. Houston, R. Stern, J. A. Purdy, and A. M. Chen, “Changes in position and volume of lung cancer target volumes during stereotactic body radiotherapy (SBRT): is image guidance necessary?” Technology in Cancer Research and Treatment, vol. 10, no. 5, pp. 495–504, 2011.
[51]
L. Simon, P. Giraud, V. Servois, and J. C. Rosenwald, “Comparative study and clinical implementation of two breathing-adapted radiotherapy techniques: dosimetric benefits for lung cancer treatment,” Cancer/Radiotherapie, vol. 10, no. 6-7, pp. 370–376, 2006.
[52]
E. Rietzel, T. Pan, and G. T. Y. Chen, “Four-dimensional computed tomography: image formation and clinical protocol,” Medical Physics, vol. 32, no. 4, pp. 874–889, 2005.
[53]
J. M. Balter, J. N. Wright, L. J. Newell et al., “Accuracy of a wireless localization system for radiotherapy,” International Journal of Radiation Oncology, Biology and Physics, vol. 61, no. 3, pp. 933–937, 2005.
[54]
R. I. Berbeco, S. B. Jiang, G. C. Sharp, G. T. Y. Chen, H. Mostafavi, and H. Shirato, “Integrated radiotherapy imaging system (IRIS): design considerations of tumour tracking with linac gantry-mounted diagnostic X-ray systems with flat-panel detectors,” Physics in Medicine and Biology, vol. 49, no. 2, pp. 243–255, 2004.
[55]
G. T. Y. Chen, J. H. Kung, and K. P. Beaudette, “Artifacts in computed tomography scanning of moving objects,” Seminars in Radiation Oncology, vol. 14, no. 1, pp. 19–26, 2004.
[56]
Q. S. Chen, M. S. Weinhous, F. C. Deibel, J. P. Ciezki, and R. M. Macklis, “Fluoroscopic study of tumor motion due to breathing: facilitating precise radiation therapy for lung cancer patients,” Medical Physics, vol. 28, no. 9, pp. 1850–1856, 2001.
[57]
J. Duan, S. Shen, J. B. Fiveash, I. A. Brezovich, R. A. Popple, and P. N. Pareek, “Dosimetric effect of respiration-gated beam on IMRT delivery,” Medical Physics, vol. 30, no. 8, pp. 2241–2252, 2003.
[58]
P. J. Keall, G. S. Mageras, J. M. Balter et al., “The management of respiratory motion in radiation oncology report of AAPM task group 76,” Medical Physics, vol. 33, no. 10, pp. 3874–3900, 2006.
[59]
S. S. Vedam, P. J. Keall, V. R. Kini, and R. Mohan, “Determining parameters for respiration-gated radiotherapy,” Medical Physics, vol. 28, no. 10, pp. 2139–2146, 2001.
[60]
L. Simon, P. Giraud, J. L. Dumas et al., “Practical recommendations for breathing-adapted radiotherapy,” Cancer/Radiotherapie, vol. 11, no. 4, pp. 214–224, 2007.
[61]
C. R. Ramsey, D. D. Scaperoth, and D. C. Arwood, “Clinical experience with a commercial respiratory gating system,” International Journal of Radiation Oncology, Biology and Physics, vol. 48, pp. 164–165, 2000.
[62]
S. B. Jiang, “Technical aspects of image-guided respiration-gated radiation therapy,” Medical Dosimetry, vol. 31, no. 2, pp. 141–151, 2006.
[63]
R. W. M. Underberg, F. J. Lagerwaard, B. J. Slotman, J. P. Cuijpers, and S. Senan, “Benefit of respiration-gated stereotactic radiotherapy for stage I lung cancer: an analysis of 4DCT datasets,” International Journal of Radiation Oncology, Biology and Physics, vol. 62, no. 2, pp. 554–560, 2005.
[64]
A. M. Berson, R. Emery, L. Rodriguez et al., “Clinical experience using respiratory gated radiation therapy: comparison of free-breathing and breath-hold techniques,” International Journal of Radiation Oncology, Biology and Physics, vol. 60, no. 2, pp. 419–426, 2004.
[65]
K. E. Sixel, M. C. Aznar, and Y. C. Ung, “Deep inspiration breath hold to reduce irradiated heart volume in breast cancer patients,” International Journal of Radiation Oncology, Biology and Physics, vol. 49, no. 1, pp. 199–204, 2001.
[66]
H. M. Lu, E. Cash, M. H. Chen et al., “Reduction of cardiac volume in left-breast treatment fields by respiratory maneuvers: a CT study,” International Journal of Radiation Oncology, Biology and Physics, vol. 47, no. 4, pp. 895–904, 2000.
[67]
L. Simon, P. Giraud, V. Servois, and J. C. Rosenwald, “Lung volume assessment for a cross-comparison of two breathing-adapted techniques in radiotherapy,” International Journal of Radiation Oncology, Biology and Physics, vol. 63, no. 2, pp. 602–609, 2005.
[68]
H. D. Kubo and L. Wang, “Introduction of audio gating to further reduce organ motion in breathing synchronized radiotherapy,” Medical Physics, vol. 29, no. 3, pp. 345–350, 2002.
[69]
E. Yorke, K. E. Rosenzweig, R. Wagman, and G. S. Mageras, “Interfractional anatomic variation in patients treated with respiration-gated radiotherapy,” Journal of Applied Clinical Medical Physics, vol. 6, no. 2, pp. 19–32, 2005.
[70]
C. Ozhasoglu and M. J. Murphy, “Issues in respiratory motion compensation during external-beam radiotherapy,” International Journal of Radiation Oncology, Biology and Physics, vol. 52, no. 5, pp. 1389–1399, 2002.
[71]
G. S. Mageras and E. Yorke, “Deep inspiration breath hold and respiratory gating strategies for reducing organ motion in radiation treatment,” Seminars in Radiation Oncology, vol. 14, no. 1, pp. 65–75, 2004.
[72]
S. S. Vedam, V. R. Kini, P. J. Keall, V. Ramakrishnan, H. Mostafavi, and R. Mohan, “Quantifying the predictability of diaphragm motion during respiration with a noninvasive external marker,” Medical Physics, vol. 30, no. 4, pp. 505–513, 2003.
[73]
A. Schweikard, G. Glosser, M. Bodduluri, M. J. Murphy, and J. R. Adler, “Robotic motion compensation for respiratory movement during radiosurgery,” Computer Aided Surgery, vol. 5, no. 4, pp. 263–277, 2000.
[74]
H. Shirato, S. Shimizu, K. Kitamura et al., “Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor,” International Journal of Radiation Oncology, Biology and Physics, vol. 48, no. 2, pp. 435–442, 2000.
[75]
Y. Seppenwoolde, H. Shirato, K. Kitamura et al., “Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy,” International Journal of Radiation Oncology, Biology and Physics, vol. 53, no. 4, pp. 822–834, 2002.
[76]
S. Shimizu, H. Shirato, S. Ogura et al., “Detection of lung tumor movement in real-time tumor-tracking radiotherapy,” International Journal of Radiation Oncology, Biology and Physics, vol. 51, no. 2, pp. 304–310, 2001.
[77]
P. G. Seiler, H. Blattmann, S. Kirsch, R. K. Muench, and C. Schilling, “A novel tracking technique for the continuous precise measurement of tumour positions in conformal radiotherapy,” Physics in Medicine and Biology, vol. 45, no. 9, pp. N103–N110, 2000.
[78]
H. Shirato, S. Shimizu, T. Kunieda et al., “Physical aspects of a real-time tumor-tracking system for gated radiotherapy,” International Journal of Radiation Oncology, Biology and Physics, vol. 48, no. 4, pp. 1187–1195, 2000.
[79]
S. L. Meeks, J. M. Buatti, L. G. Bouchet et al., “Ultrasound-guided extracranial radiosurgery: technique and application,” International Journal of Radiation Oncology, Biology and Physics, vol. 55, no. 4, pp. 1092–1101, 2003.
[80]
R. I. Berbeco, H. Mostafavi, G. C. Sharp, and S. B. Jiang, “Towards fluoroscopic respiratory gating for lung tumours without radiopaque markers,” Physics in Medicine and Biology, vol. 50, no. 19, pp. 4481–4490, 2005.
[81]
W. D. D'Souza, S. A. Naqvi, and C. X. Yu, “Real-time intra-fraction-motion tracking using the treatment couch: a feasibility study,” Physics in Medicine and Biology, vol. 50, no. 17, pp. 4021–4033, 2005.
[82]
M. J. Murphy, J. R. Adler, M. Bodduluri et al., “Image-guided radiosurgery for the spine and pancreas,” Computer Aided Surgery, vol. 5, no. 4, pp. 278–288, 2000.
[83]
S. Jiang, T. Bortfeld, A. Trofimov, E. Rietzel, G. Sharp, and N. Choi, “Synchronized moving aperture radiation therapy (SMART): treatment planning using 4D CT data,” in Proceedings of the 14th International Conference on the Use of Computers in Radiation Therapy, Seoul, Korea, 2004.
[84]
P. J. Keall, V. R. Kini, S. S. Vedam, and R. Mohan, “Motion adaptive x-ray therapy: a feasibility study,” Physics in Medicine and Biology, vol. 46, no. 1, pp. 1–10, 2001.
[85]
T. Neicu, H. Shirato, Y. Seppenwoolde, and S. B. Jiang, “Synchronized moving aperture radiation therapy (SMART): average tumour trajectory for lung patients,” Physics in Medicine and Biology, vol. 48, no. 5, pp. 587–598, 2003.
[86]
P. J. Keall, S. Joshi, S. S. Vedam, J. V. Siebers, V. R. Kini, and R. Mohan, “Four-dimensional radiotherapy planning for DMLC-based respiratory motion tracking,” Medical Physics, vol. 32, no. 4, pp. 942–951, 2005.
[87]
L. Papiez, D. Rangaraj, and P. Keall, “Real-time DMLC IMRT delivery for mobile and deforming targets,” Medical Physics, vol. 32, no. 9, pp. 3037–3048, 2005.
[88]
L. Papiez and D. Rangaraj, “DMLC leaf-pair optimal control for mobile, deforming target,” Medical Physics, vol. 32, no. 1, pp. 275–285, 2005.
[89]
D. Rangaraj and L. Papiez, “Synchronized delivery of DMLC intensity modulated radiation therapy for stationary and moving targets,” Medical Physics, vol. 32, no. 6, pp. 1802–1817, 2005.
[90]
Y. Suh, B. Yi, S. Ahn et al., “Aperture maneuver with compelled breath (AMC) for moving tumors: a feasibility study with a moving phantom,” Medical Physics, vol. 31, no. 4, pp. 760–766, 2004.
[91]
K. K. Herfarth, J. Debus, F. Lohr et al., “Extracranial stereotactic radiation therapy: set-up accuracy of patients treated for liver metastases,” International Journal of Radiation Oncology, Biology and Physics, vol. 46, no. 2, pp. 329–335, 2000.
[92]
R. B. Case, D. J. Moseley, J. J. Sonke et al., “Interfraction and intrafraction changes in amplitude of breathing motion in stereotactic liver radiotherapy,” International Journal of Radiation Oncology, Biology and Physics, vol. 77, no. 3, pp. 918–925, 2010.
[93]
D. J. W. Kim, B. R. Murray, R. Halperin, and W. H. Y. Roa, “Held-breath self-gating technique for radiotherapy of non-small-cell lung cancer: a feasibility study,” International Journal of Radiation Oncology, Biology and Physics, vol. 49, no. 1, pp. 43–49, 2001.
[94]
W. Wunderink, A. M. Romero, W. de Kruijf, H. de Boer, P. Levendag, and B. Heijmen, “Reduction of respiratory liver tumor motion by abdominal compression in stereotactic body frame, analyzed by tracking fiducial markers implanted in liver,” International Journal of Radiation Oncology, Biology and Physics, vol. 71, no. 3, pp. 907–915, 2008.
[95]
P. Giraud, E. Morvan, L. Claude et al., “Respiratory gating techniques for optimization of lung cancer radiotherapy,” Journal of Thoracic Oncology, vol. 6, no. 12, pp. 2058–2068, 2011.
[96]
P. Giraud, J. Djadi-Prat, M. Morelle et al., “Contribution of respiratory gating techniques for optimization of breast cancer radiotherapy,” Cancer Investigation, vol. 30, no. 4, pp. 323–330, 2012.
[97]
V. Beneyton, G. Billaud, C. Niederst et al., “Comparison of three dosimetric techniques to take in account lung tumor motion: gating-like technique results lead to advice the use of gating device even in the cases of pre-operative irradiation,” Cancer/Radiotherapie, vol. 14, no. 1, pp. 50–58, 2010.
[98]
P. Giraud, F. Reboul, S. Clippe et al., “Respiration-gated radiotherapy: current techniques and potential benefits,” Cancer/Radiotherapie, vol. 7, supplement 1, pp. 15s–25s, 2003.
[99]
R. Halperin, W. Roa, M. Field, J. Hanson, and B. Murray, “Setup reproducibility in radiation therapy for lung cancer: a comparison between T-bar and expanded foam immobilization devices,” International Journal of Radiation Oncology, Biology and Physics, vol. 43, no. 1, pp. 211–216, 1999.
[100]
H. D. Kubo, P. M. Len, S. I. Minohara, and H. Mostafavi, “Breathing-synchronized radiotherapy program at the University of California Davis Cancer Center,” Medical Physics, vol. 27, no. 2, pp. 346–353, 2000.
[101]
H. D. Kubo and B. C. Hill, “Respiration gated radiotherapy treatment: a technical study,” Physics in Medicine and Biology, vol. 41, no. 1, pp. 83–91, 1996.
[102]
F. J. Lagerwaard, J. R. van Sornsen de Koste, M. R. J. Nijssen-Visser et al., “Multiple “slow” CT scans for incorporating lung tumor mobility in radiotheraphy planning,” International Journal of Radiation Oncology, Biology and Physics, vol. 51, no. 4, pp. 932–937, 2001.
[103]
L. A. Dawson, K. K. Brock, S. Kazanjian et al., “The reproducibility of organ position using active breathing control (ABC) during liver radiotherapy,” International Journal of Radiation Oncology, Biology and Physics, vol. 51, no. 5, pp. 1410–1421, 2001.
[104]
W. A. Kalendar, R. Rienmuller, W. Seissler, J. Behr, M. Welke, and H. Fichte, “Measurement of pulmonary parenchymal attenuation: use of spirometric gating with quantitative CT,” Radiology, vol. 175, no. 1, pp. 265–268, 1990.
[105]
A. Pedersen, S. Korreman, H. Nystr?m, and L. Specht, “Efficacy of respiratory gated radiotherapy of breast cancer,” Radiotherapy and Oncology, vol. 64, supplement 1, article S142, 2002.
[106]
C. R. Ramsey, D. Scaperoth, and D. Arwood, “Clinical experience with a commercial respiratory gating system,” International Journal of Radiation Oncology, Biology and Physics, vol. 48, pp. 164–165, 2000.
[107]
V. M. Remouchamps, N. Letts, F. A. Vicini et al., “Initial clinical experience with moderate deep-inspiration breath hold using an active breathing control device in the treatment of patients with left-sided breast cancer using external beam radiation therapy,” International Journal of Radiation Oncology, Biology and Physics, vol. 56, no. 3, pp. 704–715, 2003.
[108]
S. Shen, J. Duan, J. B. Fiveash et al., “Validation of target volume and position in respiratory gated CT planning and treatment,” Medical Physics, vol. 30, no. 12, pp. 3196–3205, 2003.
[109]
C. D. Biancia, E. Yorke, C. S. Chui et al., “Comparison of end normal inspiration and expiration for gated intensity modulated radiation therapy (IMRT) of lung cancer,” Radiotherapy and Oncology, vol. 75, no. 2, pp. 149–156, 2005.
[110]
T. Zhang, H. Keller, M. J. O'Brien, T. R. Mackie, and B. Paliwal, “Application of the spirometer in respiratory gated radiotherapy,” Medical Physics, vol. 30, no. 12, pp. 3165–3171, 2003.
[111]
R. I. Berbeco, S. Nishioka, H. Shirato, G. T. Y. Chen, and S. B. Jiang, “Residual motion of lung tumours in gated radiotherapy with external respiratory surrogates,” Physics in Medicine and Biology, vol. 50, no. 16, pp. 3655–3667, 2005.
[112]
M. Morelle, R. Remonnay, P. Giraud, and M. O. Carrère, “Analyzing multiple learning effects in health care using multilevel modeling: application to radiotherapy at an early stage of innovation,” International Journal of Technology Assessment in Health Care, vol. 25, no. 2, pp. 232–239, 2009.
[113]
H. D. Kubo and L. Wang, “Compatibility of Varian 2100C gated operations with enhanced dynamic wedge and IMRT dose delivery,” Medical Physics, vol. 27, no. 8, pp. 1732–1738, 2000.
[114]
G. S. Mageras, E. Yorke, and S. B. Jiang, “‘4D’ IMRT delivery,” in Image-Guided IMRT, T. Bortfeld, R. Schmidt-Ullrich, W. de Neve, and D. E. Wazer, Eds., pp. 269–288, Springer, Heidelberg, Germany, 2005.
[115]
E. Yorke, G. Mageras, T. LoSasso, H. Mostafavi, and C. Ling, “Respiratory gating of sliding window IMRT,” in Proceedings of the 22nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, pp. 2118–2121, usa, July 2000.
[116]
C. X. Yu, “Intensity-modulated arc therapy with dynamic multileaf collimation: an alternative to tomotherapy,” Physics in Medicine and Biology, vol. 40, no. 9, pp. 1435–1449, 1995.