全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...

The Failure of the Cross Correlation Measurement Technique

DOI: 10.4236/oja.2015.51003, PP. 25-28

Keywords: Acoustic Array, Cross Correlation, Flow Measurement

Full-Text   Cite this paper   Add to My Lib

Abstract:

The experiment involves creating a sound wave that propagates down a pipe with 8 transducers attached at equally spaced intervals of 0.01016 m. The numerical method—the Cross Correlation Method, used to solve for the phase component, creates a high correlation value, but the speed of sound varies immensely. The method involves a Fast Fourier Transform (FFT) of the collected data, which is used to find the phase of the sound wave, and the slope of the position versus time graph, which is used to calculate the speed of sound. This high correlation value shows that the data are correct, but the numerical method for analyzing the data is incorrect.

References

[1]  Kennedy, J.L. (1993) Oil and Gas Pipeline Fundamentals. 2nd Edition, PennWell Books, Oklahoma, 3-5.
[2]  Beck, M.S. and Plaskowski, A. (1987) Cross Correlation Flowmeters, Their Design and Application. Taylor & Francis, UK.
[3]  Taylor, J.R. (2005) Classical Mechanics. University Science Books, Sausalito, 688.
[4]  Kirkpatrick, L. and Francis, G. (2010) Physics: A Conceptual World View. 7th Edition, Brooks/Cole, Cengage Learning, California, 331.