基于水冷磁体的超高场核磁共振波谱仪前置放大器系统设计与实现

, PP. 185-195

Keywords: 固体核磁共振(solidstateNMR),波谱仪,水冷磁体,前置放大器,低噪声放大器

Full-Text   Cite this paper   Add to My Lib

Abstract:

基于水冷电磁体的超高场核磁共振实验的需求,提出了一种适用于该类核磁共振波谱仪的前置放大器系统的设计方案并予以实现.该系统包括前置放大器控制器、高带前置放大器、高带混频器、宽带前置放大器以及宽带混频器,实现了通道之间的自由切换、发射与接收的快速切换以及较大的接收动态范围、较低的噪声系数.

References

[1]  Tang Jia-li(唐佳丽), Ouyang Zheng-rong(欧阳峥嵘), Zhang Xiao-dong(张晓东), et al. Optimum design of water cooling system in 20 MW resistive magnet (20 MW水冷磁体冷却水系统节能优化设计)[J]. Cryo & Supercond(低温与超导), 2010, 38 (8): 56-59.
[2]  Hong S, Field M B, Parrell J A, et al. Latest improvements of current carrying capability of niobium tin and its magnet applications[D]. IEEE T Appl Supercon, 2006, 16: 1 146-1 151.
[3]  Gan Z, Kwak H T, Bird M, et al. High-field NMR using resistive and hybrid magnets[J]. J Magn Reson, 2008, 191(1): 135-140.
[4]  Li M Z, Schiano J L, Samra J E, et al. Reduction of magnetic ?eld ?uctuations in powered magnets for NMR using inductive measurements and sampled-data feedback control[J]. J Magn Reson, 2011, 212(1): 254-264.
[5]  Iijima T, Takegoshi K. Compensation of effect of field instability by reference deconvolution with phase reconstruction[J]. J Magn Reson, 2008, 191(1): 128-134.
[6]  Zhang Zhi-yong(张智勇), Lin Mei-jin(林美金), Lin Yu-lan(林玉兰), et al. Progress of high-resolution liquid NMR spectroscopy in inhomogeneous and unstable Fields(不均匀不稳定磁场下高分辨液体核磁共振新技术的研究进展)[J]. Chinese J Magn Reson(波谱学杂志), 2010, 27(3): 310-316.
[7]  Li Zheng-gang(李正刚), Zhang Zhi(张志), Mao Wen-ping(毛文平), et al. Application of CAN bus in NMR spectrometer (CAN总线在核磁共振波谱仪中的应用)[J]. Chinese J Magn Reson(波谱学杂志), 2011, 28 (1): 59-66.
[8]  Wang Wen-juan(王文娟), Hu Peng(胡鹏), Mao Wen-ping(毛文平), et al. An ARM and CPLD based preamplifier control system for NMR spectrometers(基于ARM和CPLD的NMR谱仪前放控制设计)[J]. Chinese J Magn Reson(波谱学杂志), 2009, 26(3): 351-358.
[9]  Bao Chang-hong(包长虹), Sun Hui-jun(孙惠军), Bao Li-jun(包立君), et al. Design of broadband preamplifier for high-field NMR spectrometers(高场核磁共振波谱仪宽带前置放大器的研制)[J]. Chinese J Magn Reson(波谱学杂志), 2011, 28(2): 216-227.
[10]  Stokes H T. Tuned limiter for receiver amplifier in a fast-recovery pulsed NMR spectrometer [J]. Rev Sci Instrum, 1978, 49(7): 1 011-1 012.
[11]  Doty F D, Connick T J, Ni X Z, et al. Noise in high power, high frequency double tuned probes[J]. J Magn Reson, 1988, 77: 536-549.
[12]  Hoult D I. Fast recovery, high sensitivity NMR probe and preamplifier for low frequencies[J]. Rev Sci Instrum, 1979, 50(2): 193-200.
[13]  Hu Peng(胡鹏), Yang Liang(杨亮), Hu Shao-bin(胡少斌), et al. Design and implementation of NMR spectrometer receiver(核磁共振波谱仪接收机的设计与实现)[J]. Chinese J Magn Reson(波谱学杂志), 2011, 28(1): 42-49.
[14]  Nordmeyer-Massner J A, De Zanche N, Pruessmann K P. Noise figure characterization of preamplifiers at NMR frequencies[J]. J Magn Reson, 2011, 210: 7-15.
[15]  Qiu Zu-wen(裘祖文), Pei Feng-kui(裴奉奎). Spectroscopy of Nuclear Magnetic Resonance(核磁共振波谱)[M]. Beijing(北京): Science Press(科学出版社), 1989.
[16]  Zhang Yu-xing(张玉兴), Yang Yu-mei(杨玉梅), Jing Shou-zhao(敬守钊), et al. RF Analog Circuits and Systems(射频模拟电路与系统)[M]. Chengdu(成都): University of Electronic Science and Technology of China Press(电子科技大学出版社), 2008.