全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...

Differential Pulse Voltammetric Simultaneous Determination of Paracetamol and Omnipaque on Boron Doped Diamond Electrode: Application to Natural Tomato, Carrot, Cucumber Juices and Wastewater

DOI: 10.4236/ajac.2023.1410025, PP. 434-450

Keywords: Omnipaque, Paracétamol, Differential Pulse Voltammetry, Boron Doped Diamond Electrode

Full-Text   Cite this paper   Add to My Lib

Abstract:

This article describes the use of a boron-doped diamond electrode (BDDE) as an electrochemical sensor for the simultaneous determination of omnipaque (OMP) and paracetamol (PCM) in perchloric acid medium (HClO4 0.1 M) and in complex matrices such as tomato, carrot and cucumber juices and waste water from the Treichville University Hospital. Voltammetric studies allowed us to have well-defined oxidation peaks at distinct potentials of OMP (E = 0.5 V/SCE) and PCM (E = 0.7 V/SCE). Under optimized conditions, well-defined quantities of OMP and PCM, introduced simultaneously by metered additions, gave linear responses in concentration ranges of 259.8 - 467.2 μM for OMP and 58.73 - 116.3 μM PCM. The detection limits obtained are 7.23 μΜ and 3.6 μΜ respectively for OMP and PCM with recovery rates between 85.8% ± 0.1% and 92.6% ± 0.1% for OMP and between 99.9% ± 0.1% and 101.2% ± 0.4% for the PCM. This technique has been successfully used to simultaneously detect these pharmaceuticals in these complex environments. It allows recovery of OMP and PCM respectively up to 97.5% ± 0.0% and 91.6% ± 0.3% in tomato juice; 100.0% ± 0.0% and 95.2% ± 0.2% in carrot juice; 101.4% ± 0.1% and 97.3% ± 0.3% in cucumber juice; 100.1% ± 0.9% and 100.9% ± 0.1% in wastewater. The relevance of this technique for the simultaneous detection of OMP and PCM in tomato, carrot, cucumber juices and in waste water can be studied in the context of the contamination of certain fruits and vegetables by the substances organic pharmaceuticals released into the environment without prior treatment.

References

[1]  Schlüsener, M., Löffler, D. and Ternes, T. (2008) List of the Relevant PPs. Projet Européen KNAPPE, Deliverable D11, European Commission, 6th Framework Program, 63.
[2]  Sadezky, A., Löffler, D. and Ternes, T. (2008) Proposal of an Environmental Indicator and Classification System of Pharmaceutical Product Residues for Environmental Management. Projet Européen KNAPPE, Deliverable D12, European Commission, 6th Framework Program, 92.
[3]  Goyal, R.N. and Singh, S.P. (2006) Voltammetric Determination of Paracetamol at C60-Modified Glassy Carbon Electrode. Electrochimica Acta, 51, 3008-3012.
https://doi.org/10.1016/j.electacta.2005.08.036
[4]  Dongre, V.G., Shah, S.B., Bayes, G.S., Phadke, M. and Jadhav, V.K. (2009) Simultaneous Determination of Etodolac and Acetaminophen in Tablet Dosage Form by RP-LC. Chromatographia, 69, 1019-1023.
https://doi.org/10.1365/s10337-009-0974-6
[5]  Lv, X.D., Cui, Y.H., Xue, W.J., Yang, S.Q., Li, J.Y. and Liu, Z.Q. (2019) Comparison of Inert and Noninert Cathode in Cathode/Fe3t/Peroxymonosulfate Processes on Iohexol Degradation. Chemosphere, 223, 494-503.
https://doi.org/10.1016/j.chemosphere.2019.02.079
[6]  Jeong, J., Jung, J., Cooper, W.J. and Song, W. (2010) Degradation Mechanisms and Kinetic Studies for the Treatment of X-Ray Contrast Media Compounds by Advanced Oxidation/Reduction Processes. Water Research, 44, 4391-4398.
https://doi.org/10.1016/j.watres.2010.05.054
[7]  Tian, F.X., Xu, B., Lin, Y.L., Hu, C.Y., Zhang, T.Y. and Gao, N.Y. (2014) Photodegradation Kinetics of Iopamidol by UV Irradiation and Enhanced Formation of Iodinated Disinfection By-Products in Sequential Oxidation Processes., Water Research, 58, 198-208.
https://doi.org/10.1016/j.watres.2014.03.069
[8]  Duirk, S.E., Lindell, C., Cornelison, C.C., Kormos, J., Ternes, T.A., Attene-Ramos, M., Osiol, J., Wagner, E.D., Plewa, M.J. and Richardson, S.D. (2011) Formation of Toxic Iodinated Disinfection By-Products from Compounds Used in Medical Imaging. Environmental Science & Technology, 45, 6845-6854.
https://doi.org/10.1021/es200983f
[9]  Paracetamol.
https://www.drugs.com/paracetamol.html
[10]  Oulton, R.L., Kohn, T. and Cwiertny, D.M. (2010) Pharmaceuticals and Personal Care Products in Effluent Matrices: A Survey of Transformation and Removal during Wastewater Treatment and Implications for Wastewater Management. Journal of Environmental Monitoring, 12, 1956-1978.
https://doi.org/10.1039/c0em00068j
[11]  Nikolaou, A., Meric, S. and Fatta, D. (2007) Occurrence Patterns of Pharmaceuticals in Water and Wastewater Environments. Analytical and Bioanalytical Chemistry, 387, 1225-1234.
https://doi.org/10.1007/s00216-006-1035-8
[12]  Saracino, M.A., Petio, C., Vitali, M., Franchini, L. and Raggi, M.A. (2009) Determination of Orphenadrine Plasma Levels Using HPLC with Diode Array Detection and a Novel Solid-Phase Extraction Procedure in Psychiatric Patients. Journal of Pharmaceutical and Biomedical Analysis, 50, 501-506.
https://doi.org/10.1016/j.jpba.2009.05.010
[13]  Wang, A., Sun, J., Feng, H., Gao, S. and He, Z. (2008) Simultaneous Determination of Paracetamol and Caffeine in Human Plasma by LC-ESI-MS. Chromatographia, 67, 281-285.
https://doi.org/10.1365/s10337-007-0493-2
[14]  Arayane, M.S., Sultana, N. and Siddiqui, F.A. (2009) Simultaneous Determination of Paracetamol and Orphenadrine Citrate in Dosage Formulations and in Human Serum by RP-HPLC. Journal of the Chinese Chemical Society, 56, 169-174.
https://doi.org/10.1002/jccs.200900024
[15]  Darwish, K., Salama, I., Mostafa, S. and El-Sadek, M. (2012) Validated Stability-Indicating Reversed-Phase-HPLC Method for Simultaneous Determination of Orphenadrine Citrate, Caffeine and Aspirin. Chemical and Pharmaceutical Bulletin, 60, 1426-1436.
https://doi.org/10.1248/cpb.c12-00596
[16]  Walash, M.I., Belal, F.F., Eid, M.I. and Mohamed, S.A.A. (2011) Spectrophotometric Determination of Tizanidine and Orphenadrine via Ion Pair Complex Formation Using Eosin Y. Chemistry Central Journal, 5, Article No. 60.
https://doi.org/10.1186/1752-153X-5-60
[17]  Dinc, E. and Onur, F. (1998) Application of a New Spectrophotometric Method for the Analysis of a Ternary Mixture Containing Metamizol, Paracetamol and Caffeine in Tablets. Analytica Chimica Acta, 359, 93-106.
https://doi.org/10.1016/S0003-2670(97)00615-6
[18]  Khoshayand, M.R., Abdollahi, H., Shariatpanahi, M., Saadatfard, A. and Mohammadi, A. (2008) Simultaneous Spectrophotometric Determination of Paracetamol, Ibuprofen and Caffeine in Pharmaceuticals by Chemometric Methods. Spectrochimica Acta Part A, 70, 491-499.
https://doi.org/10.1016/j.saa.2007.07.033
[19]  Li, S.J., Deng, D.-H., Pang, H., Liu, L., Xing, Y. and Liu, S.-R. (2012) Preparation of Electrochemically Reduced Graphene Oxide-Modified Electrode and Its Application for Determination of p-Aminophenol. Journal of Solid State Electrochemistry, 16, 2883-2889.
https://doi.org/10.7312/li--16274-017
[20]  Kachoosangi, R.T., Wildgoose, G.G. and Compton, R.G. (2008) Sensitive Adsorptive Stripping Voltammetric Determination of Paracetamol at Multiwalled Carbon Nanotube Modified Basal Plane Pyrolytic Graphite Electrode. Analytica Chimica Acta, 618, 54-60.
https://doi.org/10.1016/j.aca.2008.04.053
[21]  Svorc, L., Tomcik, P., Svtkov, J., Rievaj, M. and Bustin, D. (2012) Simultaneous Square-Wave Voltammetric Determination of Paracetamol, Caffeine and Orphenadrine in Pharmaceutical Formulations Using a Cathodically Pretreated Boron-Doped Diamond Electrode. Food Chemistry, 135, 1198-1204.
https://doi.org/10.1016/j.foodchem.2012.05.052
[22]  Frag, E.Y.Z., Ali, T.A., Mohamed, G.G. and Awad, Y.H.H. (2012) Construction of Different Types of Ion-Selective Electrodescharacteristic Performances and Validation for Directpotentiometric Determination of Orphenadrine Citrate. International Journal of Electrochemical Science, 7, 4443-4464.
https://doi.org/10.1016/S1452-3981(23)19552-6
[23]  Nebsen, M., Abd El-Rahman, M.K., El-Kosasy, A.M., Salem, M.Y. and El-Bardicy, M.G. (2011) Miniaturized Membrane Sensors for the Determination of Orphenadrine Citrate Portug. Electrochimica Acta, 29, 165-176.
https://doi.org/10.4152/pea.201103165
[24]  Lourenao, B.C., Medeiros, R.A., Rocha-Filho, R.C., Mazo, L.H. and Fatibello-Filho, O. (2009) Simultaneous Voltammetric Determination of Paracetamol and Caffeine in Pharmaceutical Formulations Using a Boron-Doped Diamond Electrode. Talanta, 78, 748-752.
https://doi.org/10.1016/j.talanta.2008.12.040
[25]  Sanghavi, B.J. and Srivastava, A.K. (2010) Simultaneous Voltammetric Determination of Acetaminophen, Aspirin and Caffeine Using an In-Situ Surfactant-Modified Multiwalled Carbon Nanotube Paste Electrode. Electrochimica Acta, 55, 8638-8648.
https://doi.org/10.1016/j.electacta.2010.07.093
[26]  Ghorbani-Bidkorbeh, F., Shahrokhian, S., Mohammadi, A. and Dinarvand, R. (2010) Simultaneous Voltammetric Determination of Tramadol and Acetaminophen Using Carbon Nanoparticles Modified Glassy Carbon Electrode. Electrochimica Acta, 55, 2752-2759.
https://doi.org/10.1016/j.electacta.2009.12.052
[27]  Silva, W.C., Pereira, P.F., Marra, M.C., Gimenes, D.T., Cunha, R.R., da Silva, R.A.B., Munoz, R.A.A. and Richter, E.M. (2012) A Simple Strategy for Simultaneous Determination of Paracetamol and Caffeine Using Flow Injection Analysis with Multiple Pulse Amperometric Detection. Electroanalysis, 23, 2764-2770.
https://doi.org/10.1002/elan.201100512
[28]  Scholz, F. (2002) Electroanalytical Methods-Guide to Experiments and Applications. Springer, New York.
[29]  Kalayci, S., Ünal, U. and Somer, G. (2020) Determination of Vitamin B12 Using Differential Pulse Polarography. American Journal of Analytical Chemistry, 11, 187-196.
https://doi.org/10.4236/ajac.2020.115014
[30]  Peckov, K., Musilov, J. and Barek, J. (2009) Boron-Doped Diamond Film Electrodes—New Tool for Voltammetric Determination of Organic Substances. Critical Reviews in Analytical Chemistry, 39, 148-172.
https://doi.org/10.1080/10408340903011812
[31]  Sartori, E.R., Medeiros, R.A., Rocha-Filho, R.C. and Fatibello-Filho, O. (2009) Square-Wave Voltammetric Determination of Acetylsalicylic Acid in Pharmaceutical Formulations Using a Boron-Doped Diamond Electrode without the Need of Previous Alkaline Hydrolysis Step. Journal of the Brazilian Chemical Society, 20, 360-366.
https://doi.org/10.1590/S0103-50532009000200022
[32]  Batista, E.F., Sartori, E.R., Medeiros, R.A., RochaFilho, R.C. and Fatibello-Filho, O. (2010) Differential Pulse Voltammetric Determination of Sildenafil Citrate (Viagra®) in Pharmaceutical Formulations Using a Boron-Doped Diamond Electrode. Analytical Letters, 43, 1046-1054.
https://doi.org/10.1080/00032710903491153
[33]  Sartori, E.R., Medeiros, R.A., Rocha-Filho, R.C. and Fatibello-Filho, O. (2010) Square-Wave Voltammetric Determination of Propranolol and Atenolol in Pharmaceuticals Using a Boron-Doped Diamond Electrode. Talanta, 81, 1418-1424.
https://doi.org/10.1016/j.talanta.2010.02.046
[34]  Ardila, J.A., Sartori, E.R., Rocha-Filho, R.C. and Fatibello-Filho, O. (2013) Square-Wave Voltammetric Determination of Bezafibrate in Pharmaceutical Formulations Using a Cathodically Pretreated Boron-Doped Diamond Electrode. Talanta, 103, 201-206.
https://doi.org/10.1016/j.talanta.2012.10.033
[35]  Gil, J.S., Yanez, E.C. and Frontana-Uribe, B.A. (2022) Recent Advances on Boron Doped Diamond (BDD) Electrode as Cathode in Organic and Inorganic Preparative Electrotransformations. Current Opinion in Electrochemistry, 34, Article ID: 101004.
https://doi.org/10.1016/j.coelec.2022.101004
[36]  Salazar-Banda, G.R. andrade, L.S., Nascente, P.A.P., Pizani, P.S., Rocha-Filho, R.C. and Avaca, L.A. (2006) The Changing Electrochemical Behaviour of Boron-Doped Diamond Surfaces with Time after Cathodic Pre-Treatments, Electrochimica Acta, 51, 4612-4619.
https://doi.org/10.1016/j.electacta.2005.12.039
[37]  Koffi, K.M. and Ouattara, L. (2019) Electroanalytical Investigation on Paracetamol on Boron-Doped Diamond Electrode by Voltammetry. American Journal of Analytical Chemistry, 10, 562-578.
https://doi.org/10.4236/ajac.2019.1011039
[38]  Zheng, M., Gao, F., Wang, Q., Cai, X., Jiang, S., Huang, L. and Fei, G. (2013) Electrocatalytical Oxidation and Sensitive Determination of Acetaminophen on Glassy Carbon Electrode Modified with Graphene-Chitosan Composite. Materials Science and Engineering C, 33, 1514-1520.
https://doi.org/10.1016/j.msec.2012.12.055
[39]  Tanuja, S.B., Swamy, B.E.K. and Pai, K.V. (2017) Electrochemical Determination of Paracetamol in Presence of Folic Acid at Nevirapine Modified Carbon Paste Electrode: A Cyclic Voltammetric Study. Journal of Electroanalytical Chemistry, 798, 17-23.
https://doi.org/10.1016/j.jelechem.2017.05.025
[40]  Koffi, K.M. and Ouattara, L. (2019) Differential Pulse Voltammetric Determination of Paracetamol on a Boron-Doped Diamond Electrode: Application to Natural Tomato and Carrot Juices. Revue Ivoirienne des Sciences et Technologie, 34, 44-66.
[41]  Koffi, K.S., Foffié, T.A.A., Kouadio, K.E., Kimou, K.J., Kone, S. and Ouattara, L. (2021) Cyclic and Differential Pulse Voltammetry Investigations of an Iodine Contrast Product Using Microelectrode of BDD. Mediterranean Journal of Chemistry, 11, 244-254.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133