Study of the Effect of Acetic Acid and Phosphate on Copper Corrosion by Immersion Tests

DOI: 10.4236/msa.2024.151002, PP. 15-23

Keywords: Acetic Acid, Phosphate, Oxygen-Free Copper, Hemispherical Corrosion, Ant-Nest Corrosion

Full-Text   Cite this paper   Add to My Lib

Abstract:

It was reported that hemispheric corrosion occurred in copper tubes in an acetic acid environment. When hemispheric corrosion occurred, corrosion could easily progress if water then flowed into the copper pipe, and countermeasures were needed. Therefore, we studied the copper corrosion caused by acetic acid. The present work investigated the relationship between the corrosion form of copper and acetic acid concentration using phosphorous-deoxidized copper, and reported that hemispherical corrosion was observed at acetic acid concentrations of 0.01 to 1 vol.% (0.002 to 0.2 mol·L-1) in the immersion test. In this study, the effects of acetic acid and phosphate on copper corrosion were examined using oxygen-free copper in immersion tests. The results suggested that different concentrations of phosphate in acetic acid solutions and the presence or absence of acetic acid and phosphate affected the corrosion of copper, resulting in different corrosion forms and corrosion progress.

References

[1]  Sakai, M., Matsudaira, H., Seri, O., Amano, Y., Hiramatsu, S., Oguri, R. and Hara K. (2007) Ant’s Nest Corrosion Occurred on Copper Tubes Used for Evaporator of Alcohol Drink Dispenser. Journal of Japan Institute of Copper, 46, 221-225.
[2]  Notoya, T. (1994) Ant’s Nest Corrosion in Copper Tubes. Zairyo-to-Kankyo, 46, 281.
https://doi.org/10.3323/jcorr1991.46.281
[3]  Hamamoto, T. and Imai, M. (1991) Organic Chlorinated Solvent and Formicary Corrosion in Copper Tube. Journal of the Japan Copper and Brass Research Association, 30, 92-98.
[4]  Isobe, G. and Ueda, K. (1999) Study on Ant Nest Corrosion Test of Self Evaporating Lubricant Oil. Furukawa Electric Review, 104, 99-102.
[5]  Notoya, T., Hamamoto, T. and Kawano, K. (1989) Formicary Corrosion in Copper Tubes in Wet Atmospheric Conditions. Sumitomo Light Metal Technical Report, 30, 123-128.
[6]  Baba, H. and Kodama, T. (1995) Localized Corrosion of Copper in Wet Organic Acid Vapor. Zairyo-to-Kankyo, 44, 233-239.
https://doi.org/10.3323/jcorr1991.44.233
[7]  Bastidas, D.M., Cayuela, I. and Bastidas, J.M. (2006) Ant-Nest Corrosion of Copper Tubing in Air-Conditioning Units. Revista de Metalurgi, 42, 367-381.
https://doi.org/10.3989/revmetalm.2006.v42.i5.34
[8]  Sakai, M., Yamaguchi, K. and Kameda, Y. (2012) Ant’s Nest Corrosion on Copper Tube in Formic Acid Solution. Zairyo-to-Kankyo, 61, 389-391.
https://doi.org/10.3323/jcorr.61.389
[9]  Sakai, M., Kameda, Y. and Yamaguchi, K. (2013) Morphology of Copper Corrosion and Dissolution Rate of Copper in Formic Acid Solution. Zairyo-to-Kankyo, 62, 103-106.
https://doi.org/10.3323/jcorr.62.103
[10]  Sakai, M. and Miyao, K. (2015) Morphology of Copper Corrosion under Formic, Acetic and Propionic Acid Environment. Zairyo-to-Kankyo, 64, 452-457.
https://doi.org/10.3323/jcorr.64.452
[11]  Sakai, M., Hirakawa, T., Kyo, Y., Oya, Y. and Kawano, K. (2020) Reproduction for Corrosion Morphology of Copper in Formic and Acetic Acid Environment by Electrochemical Methods. Journal of Japan Institute of Copper, 59, 130-135.
https://doi.org/10.34562/jic.59.1_130
[12]  Yamaguchi, Y., Sasaki, T., Kano, Y., Yamada, Y. and Sakurada, O. (2023) Corrosion Morphology of Copper as a Function of Acetic Acid Concentration. Journal of Japan Institute of Copper, 62, 110-113.
https://doi.org/10.34562/jic.62.1_110